Abstract
Nondestructive evaluation (NDE) techniques were used for the tensile damage characterization in ceramic matrix composites (CMCs). Ultrasonic testing (UT) and infrared (IR) thermography were employed to assess defects and/or damage evolution before and during mechanical testing. Prior to tensile testing, a UT C-scan and a xenon flash method were performed to obtain initial defect information in light of UT C-scans and thermal diffusivity maps, respectively. An IR camera was used for in-situ monitoring of progressive damages. The IR camera measured temperature changes during tensile testing. This paper has presented the feasibility of using NDE techniques to interpret structural performance of CMCs.