Abstract

Damage evolution of rectangular concrete-filled steel tube (RCFT) column and beam-column members as documented in experimental tests is presented in this paper. An experimental database was first constructed that included RCFT tests that were reported in detail in the worldwide literature. Based on the experimental data, appropriate damage states for RCFT members, connections, and frames were defined at different levels of loading. For each damage state, the performance of the specimens was documented quantitatively with the use of deformation-based damage functions, energy-based damage functions, and ductility functions developed in this work. The paper then documents how to use these damage measures to assess capacity of RCFT columns and beam-columns within the context of a performance-based design methodology.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.