Abstract
Purpose : A system has been implemented for daily localization of the prostate through radiographic localization of implanted markers. This report summarizes an initial trial to establish the accuracy of patient setup via this system. Methods and Materials : Before radiotherapy, three radiopaque markers are implanted in the prostate periphery. Reference positions are established from CT data. Before treatment, orthogonal radiographs are acquired. Projected marker positions are extracted semiautomatically from the radiographs and aligned to the reference positions. Computer-controlled couch adjustment is performed, followed by acquisition of a second pair of radiographs to verify prostate position. Ten patients (6 prone, 4 supine) participated in a trial of daily positioning. Results : Three hundred seventy-four fractions were treated using this system. Treatment times were on the order of 30 minutes. Initial prostate position errors (σ) ranged from 3.1 to 5.8 mm left-right, 4.0 to 10.1 mm anterior-posterior, and 2.6 to 9.0 mm inferior-superior in prone patients. Initial position was more reproducible in supine patients, with errors of 2.8 to 5.0 mm left-right, 1.9 to 3.0 mm anterior-posterior, and 2.6 to 5.3 mm inferior-superior. After prostate localization and adjustment, the position errors were reduced to 1.3 to 3.5 mm left-right, 1.7 to 4.2 mm anterior-posterior, and 1.6 to 4.0 mm inferior-superior in prone patients, and 1.2 to 1.8 mm left-right, 0.9 to 1.8 mm anterior-posterior, and 0.8 to 1.5 mm inferior-superior in supine patients. Conclusions : Daily targeting of the prostate has been shown to be technically feasible. The implemented system provides the ability to significantly reduce treatment margins for most patients with cancer confined to the prostate. The differences in final position accuracy between prone and supine patients suggest variations in intratreatment prostate movement related to mechanisms of patient positioning.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Radiation Oncology, Biology, Physics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.