In this study, experiment that snow melting utilization waste heat recovery of boiler with heat pipe BACH was carried out. BACH is operation principle different from conventional heat pipes. In the experiment, 50% ethylene glycol solution were enclosed in BACH and thermocouples were attached to snow melting plate and BACH, and temperature of snow melting plate and BACH when the boiler is running were recorded with date logger. Consequently, operation of the top heat BACH using the high-temperature waste heat boiler and snow melting could be confirmed. When thermal insulation material was attached to intermediate cooled section, temperature of intermediate cooled section is higher than 30 degrees without thermal insulation material. Also, amount of heat radiation on the snow melting plate was calculated. Result of calculation, amount of heat radiation was 142W. Assuming that the entire plate is snow melting possible area, heat radiation amount per square meter was 300W.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.