Abstract

This paper summarizes the results of our researches that we have performed to clarify the mechanism of critical heat flux (CHF) for saturated and subcooled pool boiling on an upward surface with high heat capacity. The reasons why the macrolayer dryout model would be the most appropriate model for the CHF are presented. A macrolayer formation model applicable to both saturated and subcooled boiling is also introduced.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.