Abstract

Results concerning the dependence of the inverse Wiedemann effect (IWE) voltage in Fe/sub 77.5/Si/sub 7.5/B/sub 15/ glass covered amorphous wire on the external DC magnetic field are presented. In the 0.01-0.015 mT and 0.02-0.03 mT ranges for torsion annealed and as-cast wires, respectively, there is a linear dependence of the IWE voltage on the DC magnetic field. The response sensitivity increases up to about 19 V/mT when the AC current frequency increases up to about 3 kHz. DC magnetic field sensing elements, based on the IWE effect, having small dimensions, very good mechanical and corrosion resistance can be realized using glass covered amorphous wires.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.