Abstract

This study was purposed to evaluate the cytotoxicity of commercially available 3 types of prefabricated gutta-percha points and 8 types of thermoplastic endodontic obturation materials using MTT tests and agar overlay test. On MTT test, the Obtura ® showed significantly lower cell viability (16.3±0.8% vs. Control; p<0.05), which is over four times lower than those of other tested materials (p<0.05). The Diadent point ® , Sure-endo point ® , and Diadent Medium ® showed rather higher cell viability compared to that of Control (p<0.05). On agar overlay test, Sure-endo Soft ® and Sure-endo Hard ® showed a lower cytotoxicity (decolorization index = 2) compared to other tested materials (decolorization index = 3), while all the tested materials ranked as ‘moderate cytotoxic’ (response index = 2/2 or 3/2). From this study it is demonstrated that the endodontic obturation materials have various degrees of cytotoxicity, and further in vivo biocompatibility evaluation is needed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.