Abstract

To investigate the potential cytotoxicity of the bracket identification dyes commonly used in orthodontic fixed appliances. Six bracket brands representing the market in various aspects were selected. Ten sets of each bracket brand were acquired, and the identification dyes on them were scraped. They were tested for cytotoxicity at three different levels of concentration (2.5 mg/mL, 5 mg/mL, and 10 mg/mL), with the aid of a real-time cell analysis system. The results were compared within and between the groups. One-way analysis of variance and Tukey's post hoc test were used for statistical analysis. None of the six investigated dyes displayed cytotoxicity at the 2.5 mg/mL concentration. Of the investigated brands, three at 5 mg/mL and four at 10 mg/mL displayed cytotoxicity. Some of the identification dyes in this study did display cytotoxicity at the higher concentrations tested. Alternative methods for bracket identification should be considered.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.