Abstract

Esophagogastroduodenoscopies (EGD) are aerosol-generating procedures that may spread respiratory pathogens. We aim to investigate the production of airborne aerosols and droplets during Cytosponge procedures, which are being evaluated in large-scale research studies and National Health Service (NHS)implementation pilots to reduce endoscopy backlogs. We measured 18 Cytosponge and 37 EGD procedures using a particle counter (diameters = 0.3-25μm), taking measurements 10cm from the mouth. Two particle count analyses were performed: whole procedure and event-based. Direct comparison with duration-standardized EGD procedures shows that Cytosponge procedures produce 2.16× reduction (P < 0.001) for aerosols and no significant change for droplets (P =0.332). Event-based analysis shows that particle production is driven by throat spray (aerosols: 138.1× reference, droplets: 16.2×), which is optional, and removal of Cytosponge (aerosols: 14.6×, droplets: 62.6×). Cytosponge burping produces less aerosols than EGD (2.82×, P < 0.05). Cytosponge procedures produce significantly less aerosols and droplets than EGD procedures and thus reduce two potential transmission routes for respiratory viruses.