Abstract

It was presented a strong difference on cell adhesion and proliferation of functionalized vertically-aligned multi-walled carbon nanotube (VACNT) scaffolds compared to raw-VACNT. Biocompatibility in vitro tests were performed on raw-VACNT after superficial modification by oxygen plasma, which changes its superhydrophobic character to superhydrophilic. Two cytocompatibility tests were applied: 1) total lactate dehydrogenase colorimetric assay for the study of proliferating cells; and 2) cellular adhesion by scanning electron microscopy. Results showed that superhydrophilic VACNT scaffolds stimulate cell growth with proliferation up to 70% higher than normal growth of cell culture.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.