Abstract

Cycloconverter control circuitry is discussed using examples from a practical three-phase to single-phase circulating current free cycloconverter. The voltage biased cosine wave technique is used for phase control. Phase-forward and phase-back limit (PBL) pulses are superimposed on each cosine wave. Spurious gating pulses in the range 180° to 360° are suppressed. A new current zero detector is presented involving continuous monitoring of the voltage across each thyristor. Two types of circulating current elimination logic are used, suitable for 1)resistive and lagging loads, and 2)leading, resistive, and lagging loads. Auxiliary gate pulses are supplied to the incoming converter to prevent large gaps in the load current waveform.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.