Cyclic voltammetric studies of Pd(II)/Pd(0) electrode process were carried out on a Glassy Carbon Electrode (GCE) in HCl for the development of an Anodic Stripping Voltammetric (ASV) method for the determination of palladium in High-Level Nuclear Waste (HLNW). Pd(II) reduces electrochemically to Pd(0) in a wide potential range, depending upon the concentration of HCl. No significant effect of concentration was observed on the oxidation of palladium, which more or less occurs at 500 mV. Effects of HCl concentration, potential scan range, scan rate and scan repetition were studied in detail. The oxidation of palladium in HCl medium was relatively more distinct than in nitric and sulphuric acids. Maximum anodic and cathodic peak currents of unequal heights were observed at 1.0 ×10–2 M concentration of HCl. An ASV method was developed successfully on the basis of these studies for the determination of palladium in HLNW.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.