Abstract

To investigate their adequacy as energy dissipating elements during earthquakes, this paper reports on cyclic inelastic tests executed to determine the maximum strength and ductility of four concrete-filled circular steel piers joined to a foundation detail proposed to develop the full composite strength at the base of these columns. Column diameters considered were 324 and 406 mm, with D/t ratios ranging from 34 to 64. The ductility of all tested columns was found to be good, all columns being able to reach drifts of 7% before a significant loss in moment capacity occurred as a result of cracks opening on the local buckles, suggesting that concrete-filled steel tubes can be effective as bridge piers in seismic regions of North America.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.