Abstract
A statistical study was performed to evaluate the cyclic instability of steel moment connections with reduced beam sections. Based on test results of 55 full-scale specimens, regression analyses were performed to evaluate the relationships between response quantities (plastic rotation capacity and strength degradation rate) and slenderness parameters for buckling. Regressions analyses performed on a linear and a nonlinear model showed that the response quantities are highly dependent on the slenderness ratio of web local buckling, not lateral-torsional buckling. Relationships between the response quantities and the slenderness ratios for both web and flange local buckling modes were developed. For a target plastic rotation capacity, the limiting width-thickness ratio of web local buckling for seismic design is presented. An investigation of the concrete slab effect showed that it would increase both the strength and plastic rotation capacity of the reduced beam section beams under positive bending. Under negative bending, however, the slab only enhanced the plastic rotation capacity slightly, implying that the slab cannot be counted on to brace the beam bottom flange.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.