Abstract

The cyclic plasticity of nickel was studied by accomplishing room temperature fully-reversed fatigue experiments at constant plastic strain amplitudes of 1.0×10 −4 and 2.5×10 −4 on single crystal and polycrystal nickel with 290 μm grain size. The cyclic plasticity behavior within a hysteresis loop was analyzed by measuring shape characteristics of the loop. Parameters that were evaluated include the loop shape parameter, friction stress, back stress, and second derivative of stress with respect to total strain. Results indicate that these parameters correlate well with the development of dislocation substructures. In addition, at low plastic strain amplitude, polycrystal and single crystal hysteresis loops exhibit a distinct constriction. The constriction is more pronounced in single crystals cycled at the lower plastic strain amplitude.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.