Abstract

AbstractEquations for the design of a posttensioned seismic retrofit of unreinforced clay brick masonry walls are discussed, and results from an associated experimental program are reported. A total of eight full-scale multiwythe vintage solid clay brick masonry walls were subjected to uniformly distributed one-directional and reverse cyclic out-of-plane loading, of which two walls were tested as built and six walls were seismically retrofitted using unbonded posttensioning. Test wall configurations and constituent masonry materials were selected to replicate typical characteristics of historic clay brick masonry walls. The test walls were seismically retrofitted by applying varying magnitudes of posttensioning using a single tendon inserted into a cavity located at the center of each test wall. Several aspects pertaining to the seismic behavior of posttensioned masonry walls were investigated, including damage patterns, force-displacement behavior, tendon stress variation, wall secant stiffness, hysteret...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.