Abstract

Purpose. This pilot study examined the cyclic fatigue of five endodontic post systems (AccessPost, Flexi-Flange, Flexi-Post, ParaPost, and Vlock) with four core materials (Tytin silver amalgam, Ti-Core, Ketac-Silver and G-C Miracle Mix).Material and methods. In vitro cyclic fatigue was performed with a machine designed to simulate masticatory fatigue forces. An instantaneous force of 22.2 N (5 pounds) was applied to each post and core combination for a test configuration of 4,000,000 repetitions, or until failure occurred. The type of failure and number of repetitions at failure was recorded for each sample tested. Two-way analysis of variance (ANOVA) was used to compare groups.Results. All posts/core samples with Ti-Core composite and Tytin silver amalgam completed the test with no failures. All posts/core samples with Ketac-Silver material failed before the 4,000,000 test cycle configuration and all failures were core failures. All posts/core samples with G-C Miracle Mix material failed in a similar manner. Newman-Keuls multiple comparison test illustrated that, with this simulated fatigue test, Ti-Core material and Tytin silver amalgam were superior to both G-C Miracle Mix and Ketac-Silver materials. (J Prosthet Dent 1997;78: 458-64.)