Abstract

The aim of the study is to validate a customized V˙O 2max Graded Exercise Test (GXT) protocol specifically to accommodate firefighters with different cardiovascular fitness levels. Career male firefighters (N = 15) completed 3 customized GXTs on a treadmill: 1 in athletic clothes and 2 in their bunker gear to determine maximal oxygen uptake (V˙O 2max ). The on-duty task protocol was reliable, V˙O 2max values of 40.2 ± 4.6 mL·kg·min -1 and 40.3 ± 5.3 mL·kg·min -1 between trials yielded an interclass correlation of 0.911 with a typical error of 1.48 mL·kg·min -1 and a coefficient of variation of 4.0%. The validity analysis indicated consistent maximal V˙O 2 values for the GXTs yielding mean interclass correlation of 0.94 with typical error of 1.16 mL·kg·min -1 and a coefficient of variation of 2.9%. The customized GXT for structural firefighters has shown to be a reliable, valid, and applicable method of testing cardiovascular fitness in firefighters.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call