Abstract

Traumatic aniridia from combat ocular trauma can cause visual disability. A 41-year-old male Army Veteran was referred for evaluation of light sensitivity and glare secondary to subtotal traumatic aniridia of his left eye from an improvised explosive device blast. A custom-made artificial iris prosthesis was implanted in the ciliary sulcus and secured using Gore-Tex sutures. After surgery, the patient reported improvement of his light sensitivity and quality of life. The custom iris prosthesis is a surgical option for visual disability resulting from traumatic aniridia from combat ocular trauma.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.