Abstract
We investigated the potential application of the genetic algorithm in the analysis of X-ray fluorescence spectra from measurement of lead in bone. Candidate solutions are first designed based on the field knowledge and the whole operation, evaluation, selection, crossover and mutation, is then repeated until a given convergence criterion is met. An average-parameters based genetic algorithm is suggested to improve the fitting precision and accuracy. Relative standard deviation (RSD%) of fitting amplitude, peak position and width is 1.3-7.1, 0.009-0.14 and 1.4-3.3, separately. The genetic algorithm was shown to make a good resolution and fitting of K lines of Pb and g elastic peaks.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.