Abstract

Three-phase dual active bridge (3p-DAB) converter is widely used in high-power bidirectional power transfer applications, due to its unique high power density and easy implementation of soft switching. In this paper, the start-up process of the 3p-DAB converter is studied. The cause of high current stress, especially in the case of heavy-load start-up is analysed, and a new start-up control strategy for the start-up process is proposed. The control strategy is helpful to reduce the current stress of the transformer and the switches by adjusting the duty-cycle and the phase shift angle coordinately without adding any other hardware circuits. Finally, based on a TMS320F28377D + XC6SLX25 controller, a 30kW 3p-DAB converter prototype with input voltage 650-750V and output voltage 400-500V is developed to verify the effectiveness of the proposed start-up strategy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.