Abstract
This paper describes how current mode control provides active damping for boost converters with constant power loads. Small-signal control-to-output transfer functions are derived for peak or valley current mode controlled boost converter with a downstream regulated converter modeled as constant power load. Furthermore, it is shown how load current feedforward presents an effective way to improve power load transient responses. Modeling and design approaches are validated by test circuit simulations, demonstrating stable operations using current mode control under constant power loads, and improved power step load transient responses based on load current feedforward.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Circuits and Systems I: Regular Papers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.