Abstract
It has been previously suggested to use multiple reference frame (MRF) structures, based on proportional-integral controllers in synchronous reference frames (SRFs), to suppress current harmonics caused by nonlinearities in multiphase drives. However, the rotational transformations are computationally demanding. In Part 1, the three-phase strategy based on resonant controllers (RCs) implemented in an SRF has been extended to any phase number. Nevertheless, while the computational burden of MRF and multiple RC (MRC) schemes has been assessed for three-phase systems in previous papers, it is yet to be studied for other numbers of phases. Part 2 analyzes the computational load of the MRC and MRF strategies as a function of the phase number and of the highest harmonic order to be compensated. It is proved that the former provides a resource saving with respect to the latter that decreases with the phase number and increases with the highest harmonic order under consideration. It is also concluded that the MRC strategy is particularly preferable in machines with even phase number (e.g., a multiple of six).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.