Abstract

Renewable based power generation is rising rapidly due to high energy demand and carbon issues. Partial shading effect of the PV system leads to a significant reduction of the energy yield and quantity of reduction is depending on the geometry of shading effect. The incremental conductance and integral controller are used in this paper to display the maximum power point in the PV device. During bad weather conditions, insulated PV systems do not have enough power to supply the consumer. The key suggestions of this paper are to use the deficient power needed for the PV system through grid and to fed the PV system surplus power to the grid. The new control mode is used to monitor the PV current that uses two control loops for feedback. The current mode control system is a scheme for regulating electronic DC-DC power converters. On a PV system using MATLAB/SIMULINK a complete model of 100KW grid connected solar photovoltaic system using current mode controlled two-level three-phase VSC.

Highlights

  • The use of renewable-based power generation reduced high demand and carbon problems

  • In PV system it depends on temperature, level of irradiance, and generation of power reduced by partial shading conditions

  • The PV system was created at a multiple peak point, under partial shading conditions

Read more

Summary

Introduction

The use of renewable-based power generation reduced high demand and carbon problems. In PV system it depends on temperature, level of irradiance, and generation of power reduced by partial shading conditions. The PV system was created at a multiple peak point, under partial shading conditions. High performance STMPPT technique based on ACMC to monitor the true peak of PV device under PSC. In the PV plane, the MPPT algorithm uses a trapezoidal area which contains all possible GMPPs for any PSC to reduce the voltage range to be tracked. Due to its complex monitoring capability, the GMPPT control technique, the P&O algorithm is used under uniform irradiance conditions, and the MPP voltage and current are continuously monitored. When partial shading is detected, the FWA is used to determine the GMPP, owing to its good exploration and exploitation characteristics, and fast convergence [3]

Grid Connected PV system
Three phase VSC model
Reference Signal Generator
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.