Abstract

abstract: The heritage of modern architecture in exposed reinforced concrete has been shown pathological manifestations affecting the structural safety and functionality of the buildings. The manifestations are, primarily, associated with the steel corrosion; however published data obtained from site surveys, on the Brazilian architectural heritage and related to the issue, are still scarce in the literature. Thus, the aim of the study is to assess the current condition of the exposed concrete façades reinforcement of the Vilanova Artigas building, a Brazilian architectural heritage, opened in 1969. Legal restrictions limited the destructive tests and sampling areas. The history of the interventions, environmental aggressiveness and preliminary inspection (in the parent concrete and patch repairs) provided qualified information for analyzing in situ testing results. In the sampling areas physical, chemical and electrochemical tests were carried out. The façades surfaces are naturally porous, irregular, with concrete segregation and corrosion products stains; 24% of the concrete was replaced with proprietary mortar repair. In patch repairs, the average carbonation depth ranged from 3 to 29 mm, in concrete it ranged from 15 to 30 mm. The reinforcement cover ranged from 8 to 33 mm. Corrosion potential maps, with equipotential lines drawn at 50 mV intervals, indicated the corrosion-prone areas, where there is a concentration of lines with a variation equal to or greater than 150 mV. The presence of corrosion products, detected in the visual examination of the reinforcement under the patch repairs, validated the active corrosion state. The rough surface of the concrete, the low cover to depassivated reinforcement and the active corrosion state emphasize the need for monitoring the façades and the urgency of implementing a preventive maintenance plan, along with a conservation project in order to preserve the heritage values of the building.

Highlights

  • Samples of the heritage of modern architecture in exposed reinforced concrete, built in the second half of the 20th century, have been shown pathological manifestations affecting the structural safety and functionality of the buildings

  • These characteristics favor the deposition of particulate material, penetration of water and aggressive agents, which can be evidenced by dirt stains and stains of steel corrosion products present throughout the façade extension

  • The present article presented the results from inspections for assessment of the current conditions of reinforcement in the exposed concrete façades of Vilanova Artigas building

Read more

Summary

Introduction

Samples of the heritage of modern architecture in exposed reinforced concrete, built in the second half of the 20th century, have been shown pathological manifestations affecting the structural safety and functionality of the buildings. Some groups are focusing their studies to the modern architecture materials, there are still scarce published works on the review of interventions in exposed reinforced concrete in terms of the methodological aspect and impact on the heritage values [2]–[6], as well as experimental researches [7], [8] that relate the concrete and patch repair and finish mortar technologies to the conservation of these structures

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.