Abstract
We investigated the interaction of a high-voltage solar array with a plasma simulating a low Earth orbit environment. We measured the plasma-coupling currents of DC-voltage biased solar array models in an argon plasma in a large space chamber. At the positive bias voltage, the plasma-coupling current increased considerably with an increase of bias voltage above 100 V. The current at the negative bias voltage was smaller than at the positive bias voltage, but discharges occurred at about -200 to -300 V.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.