Abstract
With current science and policy needs, more attention is being given to expanding and improving air sampling of semivolatile organic contaminants (SVOCs). However, a wide range of techniques and configurations are currently used (active and passive samplers, different deployment times, different sorbents, etc.) and as the SVOC community looks to assess air measurements on a global scale, questions of comparability arise. We review current air sampling techniques, with a focus on sampling artifacts that can lead to uncertainties or biases in reported concentrations, in particular breakthrough, degradation, meteorological influences, and assumptions regarding passive sampling. From this assessment, we estimate the bias introduced for SVOC concentrations from all factors. Due to the effects of breakthrough, degradation, particle fractions and sampler uptake periods, some current passive and active sampler configurations may underestimate certain SVOCs by 30-95%. We then recommend future study design, appropriateness of sampler types for different study goals, and finally, how the SVOC community should move forward in both research and monitoring to best achieve comparability and consistency in air measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.