Abstract

While considerable attention has been directed to reducing the x-ray dose of individual imaging studies, there is little information available on the cumulative dose during imaging-intensive hospitalizations. We used a radiation-sensitive badge on 12 patients admitted with SAH to determine if this approach was feasible and to measure the extent of their x-ray exposure. After obtaining informed consent, we assigned a badge to each of 12 patients and used it for all brain imaging studies during their ICU stay. Cumulative dose was determined by quantifying exposure on the badge and correlating it with the number and type of examinations. The average skin dose for the 3 patients who had only diagnostic DSA without endovascular intervention was 0.4 Gy (0.2-0.6 Gy). The average skin dose of the 8 patients who had both diagnostic DSA and interventions (eg, intra-arterial treatment of vasospasm and coiling of aneurysms) was 0.9 Gy (1.8-0.4 Gy). One patient had only CT examinations. There was no effort made to include or exclude the badge in the working view during interventions. It is feasible to incorporate a film badge that uses a visual scale to monitor the x-ray dose into the care of hospitalized patients. Cumulative skin doses in excess of 1 Gy were not uncommon (3/12) in this group of patients with acute SAH. This approach could provide a measure of the cumulative dose and is a convenient tool to quantify the effect of dose-reduction strategies.

Highlights

  • AND PURPOSE: While considerable attention has been directed to reducing the x-ray dose of individual imaging studies, there is little information available on the cumulative dose during imaging-intensive hospitalizations

  • Cumulative skin doses in excess of 1 Gy were not uncommon (3/12) in this group of patients with acute SAH. This approach could provide a measure of the cumulative dose and is a convenient tool to quantify the effect of dose-reduction strategies

  • The study was initiated after training our CT and angiography technologists to apply the badge for each x-ray study

Read more

Summary

Objectives

Our goals were to determine how this device could be incorporated into the clinical environment and to provide a measure of potential ranges of cumulative x-ray dose in this patient group, specific for the treatment algorithm of our hospital. Our goal was to record exposure from all in-hospital x-ray examinations

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call