Abstract

A problem of Pancreatic CT scanning is the discrimination between the pancreas and the adjacent gastrointestinal tract. Generally we administer a dilution of gastrografin internally to make the discrimination. The degree of dilution has been decided by experience at each hospital.When the consistency of the contrast medium is low in density, an enhancement effect cannot be expected, but when the consistency is high, artifacts appear. We have experimented on the degree of the dilution and CT-No to decide the optimum consistency of gastrografin for the diagnosis of pancreatic disease.Statistical analysis of the results show the optimum dilution of gastrografin to be 1.5%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.