Abstract

A 950 keV X-ray source with small focal spot using a linear accelerator has been developed. By installing a focusing mechanism of electron beam, smaller focal spot (0.3 mm in FWHM of the line spread function) is successfully achieved at 950 keV. 9.3 GHz (X-band) radio frequency is used for accelerating electrons in order to make the size of X-ray source smaller, compared to lower radio frequency such as 3.0 GHz (S-band). Size and weight of the developed X-ray source are W 600 mm × D 800 mm × H 500 mm and 230 kg, respectively. Clearer transmission images using a rectangular groove sample are obtained with small spot setup, compared to conventional one. CT images are also obtained for an engine block, and we demonstrated that advantage of 950 keV X-ray source for CT imaging such as improvement of interior visibility and decrease of artefact, compared to a 450 kV X-ray source. Therefore, we are convinced that this 950 keV X-ray source is widely useful for industrial non-destructive inspection of large structures, because of compactness, high transmission ability and spatial resolution.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call