Abstract
BackgroundSacroiliac-percutaneous-screw-placement (SPSP) for unstable-posterior-pelvic-ring-injuries (UPPRI) might be associated with severe neurovascular complications because of screw-mal-position. The aim of the present study was to analysis the effectivity of computer-tomography-guided (CTG)-SPSP including accuracy of screw-placement, quality of injury-reduction and documentation of perioperative-complications. Additionally, procedure-dependent radiation-dose and outcome should be analysed. MethodsA consecutive cohort of 71 patients with UPPRI was operated by CTG-SPSP at a single trauma level 1 hospital. 136 sacroiliac screws were inserted to S1 and S2. Postoperatively, by the use of a computerised-radiologic-work-station all screws were visualised three-dimensionally. Their distancesmin to the sacral-borders in anterior-posterior and cranio-caudal direction as well as to the neuroforamen S1/S2 were determined. After CTG-SPSP, injury-dislocation in anterior-posterior and cranio-caudal direction was quantified. Local and general complications were documented during the 30-day-period. In 55 patients (77.5%) a follow-up-investigation (29.1±19.1 months) was performed. Results132 screws (97.1%) were placed completely intraosseous, 3 screws (2.2%) perforated up to 1.0mm (n(S1)=one screw; n(S2)=two screws), and one screw (0.7%) extended 2.2mm into the S2-neuroforamen without contact to neural structures. Postoperative dislocationanterior-posterior was 1.3±0.9mm and dislocationcranio-caudal 1.5±0.9mm. No procedure-associated-complication was observed. Operation time showed a significant “learning curve” during the six-year study period (initially: 88.6±60.3min; finally: 44.3±24.6min). Perioperative effective-radiation-dose for patientsmale was 5.9±3.1mSv and for patientsfemale 8.7±4.5mSv. All injuries healed and 33 patients (46.5%) had metal removal after 11.0 (±4.9) months. Only two (5.0%) out of 40 patients complained persistent UPPRI-related pain so they were not able to restart work. ConclusionsThe CTG-SPSP is a safe procedure for UPPRI-stabilisation especially in S1 but also in S2. Injury reduction was excellent and no procedure associated complications were observed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.