Abstract

In this series, 35 patients with medical renal disease had renal biopsy guided by computed tomography (CT). Biopsies were done by a coaxial technique in which a thin-walled 16 guage guide needle is placed adjacent to the renal capsule of the lower pole. An 18 gauge cutting needle is then placed through the guide needle, and multiple samples (2 to 4) are obtained with an automated biopsy gun. Adequacy of specimens is immediately checked in the CT suite using low-power microscopy. Specimens are submitted for light, electron, and immunofluorescence microscopy. Adequate tissue for definite diagnosis was obtained in 33 of the 35 patients (94%). One patient had moderate postbiopsy bleeding and was hospitalized. There were no major complications. CT-guided renal biopsy using a coaxial technique and automated biopsy gun is an effective means of obtaining tissue for the evaluation of medical renal disease.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.