Abstract

ObjectivesCervical component of thymus is noted more in children and young adults than in older age group. CT texture (lobules of soft tissue interspersed with fat), similarity with CT density of mediastinal thymus and continuity with mediastinal thymus on sagittal/coronal images, are given as the criteria for diagnosis of the cervical thymus. But CT densities of cervical and mediastinal components of the thymus may vary. The purpose of our study was to compare CT densities of cervical and mediastinal parts of the thymus, in cases where ultrasonography correlation was available.MethodsWe retrospectively identified 22 patients who had undergone CT between May 2015 and May 2017 and in whom ultrasonography (USG) correlation was available. CT densities of cervical and mediastinal components of thymus were measured.ResultsCT density of cervical thymus is lower than the CT density of mediastinal thymus by ~ 25 HU.There is a moderate positive correlation between CT densities of cervical and mediastinal parts of the thymus.CT densities of both cervical and mediastinal thymus were found to reduce with age, but the reduction was statistically significant only in the cervical thymus in this study.ConclusionsCT densities of cervical and mediastinal components of the thymus may vary, with CT density of cervical thymus being lower. There is a positive correlation between CT densities of cervical and mediastinal parts of the thymus.CT density of cervical thymus reduces with age.Understanding these may help avoid confusion on CT and avoid the need for correlative USG, saving time and effort.

Highlights

  • There is a difference between Computed tomography (CT) densities of cervical and mediastinal parts of thymus (p 0.001)

  • Mean value of CT density of cervical thymus is lower than CT density of mediastinal thymus by ~ 25 units (Table 1) when 22 patients were considered together

  • Our study demonstrates that CT density of cervical part of thymus may vary from that of mediastinal part of the thymus, with density of cervical thymus being lower than the density of mediastinal component

Read more

Summary

Objectives

Cervical component of thymus is noted more in children and young adults than in older age group. CT densities of cervical and mediastinal components of the thymus may vary. The purpose of our study was to compare CT densities of cervical and mediastinal parts of the thymus, in cases where ultrasonography correlation was available. Methods: We retrospectively identified 22 patients who had undergone CT between May 2015 and May 2017 and in whom ultrasonography (USG) correlation was available. CT densities of cervical and mediastinal components of thymus were measured. CT density of cervical thymus is lower than the CT density of mediastinal thymus by ~ 25 HU. 2. There is a moderate positive correlation between CT densities of cervical and mediastinal parts of the thymus

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call