Abstract

It is demonstrated that a common-line method can assemble a three-dimensional oversampled diffracted intensity distribution suitable for high-resolution structure solution from a set of measured two-dimensional diffraction patterns, as proposed in experiments with an X-ray free-electron laser (XFEL) [Neutze et al. (2000). Nature (London), 406, 752-757]. Even for a flat Ewald sphere, it is shown how the ambiguities due to Friedel's law may be overcome. The method breaks down for photon counts below about 10 per detector pixel, almost three orders of magnitude higher than expected for scattering by a 500 kDa protein with an XFEL beam focused to a 0.1 microm diameter spot. Even if 10(3) orientationally similar diffraction patterns could be identified and added to reach the requisite photon count per pixel, the need for about 10(6) orientational classes for high-resolution structure determination suggests that about 10(9) diffraction patterns must be recorded. Assuming pulse and readout rates of approximately 100 Hz, such measurements would require approximately 10(7) s, i.e. several months of continuous beam time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.