Abstract

This paper describes a simple model-free (i.e., empirical) control strategy for crystal size tuning in a continuously operated tubular crystallizer. The crystallizer is designed for a seeded cooling crystallization process and acetylsalicylic acid crystallization from an ethanol solution was used as model system. Using a crystal size distribution (CSD) analyzer and minor initial studies, we developed a feedback controller that accurately tuned the mean crystal size within the range of 90–140 μm. In addition, we created a cleaning concept for long-term runs based on a consistency study, which demonstrated that the CSD of the products remained robust when process settings were kept constant. Sufficiently small and uniform seed crystals were generated via ultrasound irradiation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call