Abstract

Pressures below 10 −10 torr can be maintained in large LHe cooled UHV systemsby increasing the available active cryosorbing surface area. Clean metal oxides (metal sponges) can provide the required surface area increase for higher adsorption capacities as well as for enhancing the pumping speed at extremely low pressures. Metal sponges have several advantages over the conventional cryosorbers viz. molecular sieves and charcoals. The adsorption isotherms of H 2 and He at 4.3 K on metals (Al, stainless steel, Nb) and metal oxides (Al 2O 3, Nb 2O 5) are given here in the pressure range 10 −14 − 10 −6 ton. An extractor gauge is used at LHe temperature to obtain this isotherm data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.