Abstract

For the validation and qualification programme of the Short Wavelength Spectrometer in the Infrared Space Observatory, we designed, built and tested a special set-up for vibration testing at cryogenic temperatures. This set-up has proved its usefulness and is fully operational; its design and performance are discussed here. The set-up can be cooled down to 80 K, using liquid nitrogen as a coolant. Loads of up to about 1 kg can be exposed to vibration levels representative for a launch. The mechanical transfer of the set-up is virtually flat up to 2000 Hz, while the cross-coupling between the vibration axes is no more than about 5%. The time for cooling down can be as short as 30 min, while warming up takes less than an hour.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.