Abstract

A supercritical helium (SHE) circulation pump, a jet pump, and a cold compressor were designed and manufactured as the first step of cryogenic component development for a large-scale cryogenic system which is required for the Fusion Experimental Reactor (FER). The SHE circulation pump achieved 320-g/s flow rate with an 0.08-MPa pressure head at 4.6 K, making it the biggest cold pump in the world. The jet pump’s mass flow ratio was about 1.0 with an 0.07-MPa pressure head at about 10 K. The cold compressor was successfully operated with an inlet vapor pressure of 0.053 MPa (3.7 K), and outlet pressure of 0.12 MPa, and a mass flow rate of 60 g/s. The designs and test results are described in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.