Abstract

A 50 cm diameter, lightweight, Amersil TO8E, fused-natural-quartz mirror with a single arch cross section was tested at the NASA/Ames Research Center Cryogenic Optics Test Facility to measure cryogenic distortion and hysteresis. The mirror was cooled to 77 K in four serial tests and the mirror figure was measured with a phase-measuring interferometer. On the basis of the repeatability of room temperature and cryogenic optical measurements, it was determined that the Single Arch Mirror had no measurable hysteresis and displayed repeatable cryogenic distortion. The Cryogenic Optics Test Facility, optical and thermal test methods, test results, and measurement accuracy are described.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call