Abstract
ABSTRACT Measurements of cross-modulation effects in a commercial medium power S-band TWT are reported. The tube was fed with two simultaneous monochromatic input signals of frequencies 2.15 and 3.80 Ohz. The relations between the cross-modulation and the non-linear distortion with only one of the signals present are investigated and found to be in very good agreement with a theoretical analysis. For the two-signal case the non-linear amplitude and phase distortions in various representations (compression, AM to PM cross-conversion, etc.) are given as functions of parameters like the helix voltage and the output power. It is confirmed that a low helix voltage gives low AM to PM conversion and low AM to PM cross-conversion, while a high helix voltage gives a good amplitude linearity, i.e. low compression and amplitude cross-modulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.