Abstract
The magnetic field transverse to the sensing axis may affect the performance of magnetic sensors. In the case of fluxgates, this effect is not as dramatic as it is for AMR sensors, but it still may cause errors up to 40 nT in the Earth's field. We performed measurements on voltage output fluxgate sensors of various constructions. Ring-cores are the most susceptible, showing around 10 nT error for 50 μT perpendicular field, while Vacquier-type (bar-core) sensors suppress the crossfield by their shape anisotropy. Racetrack fluxgates are the best candidates for crossfield resistant low-noise sensors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.