Abstract

AbstractBackgroundGlymphatic system (GS) is a recently discovered brain‐wide perivascular fluid transport system in the cerebral nervous system (CNS)(Benveniste H et al., 2019) The impairment of glymphatic transport has been demonstrated to be associated with several neurological diseases, in particular the vascular cognitive impairment and dementia (VCID)(Tang J et al., 2022). The diffusion tensor analysis along the perivascular space (DTI‐ALPS) was proposed to non‐invasively evaluate the GS clearance dysfunction which has been used to investigate the GS in various pathologies(Taoka T et al., 2017, Hsu JL et al., 2022). However, studies on the cross‐vendor and test‐retest reliability of DTI‐ALPS method are lacking. The current study aimed to perform cross‐vendor, inter‐rater and test‐retest validations of DTI‐ALPS method by using a cohort from the MarkVCID consortium.MethodFifty participants’ DTI data from the MarkVCID consortium (consists of 7 sites) were included in this study: 15 participants were scanned on four MRI scanners; 35 participants underwent two MR scans within 14 days. The DTI data were acquired used a single shell, b = 1000s/mm2, 40‐direction with a voxel size of 2.02.02.0mm3 and six b = 0 s/mm2 on 3T MR scanners from seven sites, including two Siemens systems, one Philips system and one GE system. Two pipelines by using DSI studio and FSL software were developed for data processing and ALPS index calculation (Figure 1). The mean ALPS (mALPS) index was obtained by the average of bilateral ALPS index and was used for testing the inter‐rater, cross‐vendor and test‐retest reliability. The association between mALPS index and Montreal Cognitive assessment (MoCA) scores were evaluated using a general linear model with age and gender as covariate.ResultThe Bland‐Altman plot and scatterplot illustrated the validation results of the mALPS index analyzed using DSI studio and FSL pipelines (Figure 2). The mALPS index demonstrated favorable inter‐scanner reproducibility (ICC = 0.77 to 0.95, P< 0.001), inter‐rater reliability (ICC = 0.96 to 1, P< 0.001) and test‐retest repeatability (ICC = 0.89 to 0.95, P< 0.001). A significantly positive correlation was observed between mALPS index and MoCA scores (r = 0.502, P< 0.01) (Figure 3).ConclusionThe mALPS index offers a robust potential biomarker for evaluating GS clearance function in VCID.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call