Abstract
ObjectiveThe extent to which adverse cognitive effects (ACEs) to a specific antiepileptic drug (AED) affect the chance of developing ACEs to other AEDs (i.e., cross-sensitivity) is unknown. We investigated the rates of cross-sensitivity of ACEs among AEDs and examined the association between clinical characteristics and occurrence of having ACEs to multiple AEDs in adults with epilepsy. MethodsThe rates of cross-sensitivity of intolerable ACEs (IACEs; i.e., ACEs leading to dosage reduction or discontinuation) and the non-AED predictors of IACEs were investigated in 2269 patients who had taken at least two AEDs at a single center. We accounted for AED load and looked for specific cross-sensitivities between AEDs as well as cross-sensitivity based on the AED mechanism of action. ResultsAmong the 2269 patients, the highest rates of IACEs were seen with TPM (26.3%), ZNS (9.8%), PHT (8.8%), and VPA (8.5%). Intolerable ACEs to two or more AEDs occurred in 100 patients (4.4%). History of psychiatric condition(s) and absence seizure type were independent predictors of IACEs to two or more AEDs. High rates of cross-sensitivity of IACEs were seen between phenytoin (PHT) and lamotrigine (LTG), valproate (VPA) and phenytoin, and valproate and zonisamide (ZNS). For example, of patients who had IACEs to VPA and were also prescribed ZNS, 46.2% had IACEs to ZNS (abbreviated as VPA→ZNS: 46.2%); of patients who had IACEs to ZNS and were also prescribed VPA, 37.5% had IACEs to VPA (abbreviated as ZNS→VPA: 37.5%). Other results are as follows: LTG→PHT: 28.6%, PHT→LTG: 20.0%, PHT→VPA: 42.9%, and VPA→PHT: 27.3%. No specific cross-sensitivities were found among AEDs sharing a similar mechanism of action. SignificanceThe probability of ACE intolerability to an AED can increase if a patient developed ACE intolerability to another AED. The cross-sensitivity rates for ACE intolerability between LTG and PHT, PHT and VPA, and VPA and ZNS were found to be particularly high. The cross-sensitivity rates provided here may be clinically useful for predicting ACE intolerability in patients taking certain AEDs and for AED selection in individual patients.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.