Abstract

Background The lost guidewire in central venous catheterization is a commonly described complication. The percutaneous endovascular retrieval method is safe and has a very low complication rate. Objectives Guidewires extending to the inferior cava vein are usually retrieved via the femoral vein. Under special circumstances, femoral venous access may be impossible and alternative vascular approaches are required. Case report We report a case in which we used an alternative vascular approach, from the subclavian site contralateral to the insertion, in a patient with extensive inguinal burn injuries. Conclusions Cross-over subclavian retrieval can be an alternative approach for retrieval of a lost guidewire, but it involves an increased risk of puncture-related complications such as pneumothorax.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.