Abstract

We report a novel approach for the detection of volatile compounds employing electrostatically driven drumhead resonators as sensing elements. The resonators are based on freestanding membranes of alkanedithiol cross-linked gold nanoparticles (GNPs), which are able to sorb analytes from the gas phase. Under reduced pressure, the fundamental resonance frequency of a resonator is continuously monitored while the device is exposed to varying partial pressures of toluene, 4-methylpentan-2-one, 1-propanol, and water. The measurements reveal a strong, reversible frequency shift of up to ∼10 kHz, i.e., ∼5% of the fundamental resonance frequency, when exposing the sensor to toluene vapor with a partial pressure of ∼20 Pa. As this strong shift cannot be explained exclusively by the mass uptake in the membrane, our results suggest a significant impact of analyte sorption on the pre-stress of the freestanding GNP membrane. Thus, our findings point to the possibility of designing highly sensitive resonators, which utilize sorption induced changes in the membrane's pre-stress as primary transduction mechanism.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.