Abstract

Perfect absorption at a resonance wavelength and extremely low absorption at the wavelength range of off-resonance in a one-port optical cavity is required for refractive index (RI) sensing with high signal contrast. Here, we propose and analyze an absorption-enhanced Fabry–Perot (MAFP) cavity based on a critical coupling condition in a near-infrared wavelength range. For a one-port cavity, a thick bottom Au is used as a mirror and an absorber. To achieve the critical coupling condition, a top dielectric metasurface is employed and tailored to balance the radiation coupling and the absorption coupling rates, and the one-port cavity is theoretically analyzed using temporal coupled-mode theory. We investigate two types of MAFP structures for gas and liquid. The gas MAFP cavity shows a sensitivity of ~ 1388 nm/RIU and a full-width at half-maximum of less than 0.7 nm. This MAFP cavity resolves the RI change of 5 × 10−4 with a reflectance signal margin of 50% and achieves a signal contrast of ~ 100%. The liquid MAFP cavity shows a sensitivity of ~ 996 nm/RIU when RI of liquid changes from 1.30 to 1.38. With tailoring the period of the metasurface maintaining its thickness, a signal contrast of ~ 100% is achieved for each specific RI range.

Highlights

  • Perfect absorption at a resonance wavelength and extremely low absorption at the wavelength range of off-resonance in a one-port optical cavity is required for refractive index (RI) sensing with high signal contrast

  • The lossless dielectric metasurface is an appropriate selection for use in absorption enhanced metasurface-Au Fabry–Perot (MAFP) structures, as it can achieve the necessary reflectance without material loss

  • We proposed and analyzed one-port MAFP cavities with a near-perfect absorption at a resonance wavelength and a near-perfect reflectance at an off-resonance wavelength range

Read more

Summary

Introduction

Perfect absorption at a resonance wavelength and extremely low absorption at the wavelength range of off-resonance in a one-port optical cavity is required for refractive index (RI) sensing with high signal contrast. Based on the understanding of the effect of the top dielectric metasurface on the coupling condition, two different types of a MAFP cavity for gaseous and liquid analytes sensing are investigated.

Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call