Abstract

The critical heat fluxes (CHFs) of subcooled water flow boiling are systematically measured for the flow velocities (u = 4.0 to 13.3 m/s), the outlet subcoolings (ΔTsub,out = 3 to 129 K) and the outlet pressure (Pout = 800 kPa). The SUS304 test tubes of 3, 6, 9 and 12 mm in inner-diameter, d, and 33, 66, 99 and 133 mm in length, L, respectively for L/d = 11 are used. The CHFs first become lower and then become higher with the increase in subcooling. The CHFs for four different inner-diameters with L/d = 11 measured here become higher with the decrease in the diameter. CHF correlation for the latter increasing regime was given in non-dimensional form against average outlet subcoolings based on the experimental data. The correlation can describe not only the CHFs obtained in this work at the outlet pressure of 800 kPa but also the authors’ published CHFs (1284 points) for the wide range of Pout = 159 kPa to 1 MPa, d = 6, 9 and 12 mm, L = 49, 99 and 149 mm, ΔTsub,out = −4 to 130 K and u = 4.0 to 13.3 m/s within 15% difference for 50 K≤ΔTsub,out≤130 K and within +30 to −10% for 30 K<ΔTsub,out<50 K.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.