Abstract

In this work, the effect of flow oscillations on critical heat flux (CHF) is investigated for water flow in vertical round tubes at low-pressure, low-flow (LPLF) conditions. An experimental study has been conducted to investigate the difference in CHF between forced and natural circulations, and between stable and oscillating flow conditions with three vertical round tube test sections (5.0 mm ID×0.6 m in length, 6.6 mm ID×0.5 m in length, and 9.8 mm ID×0.6 m in length) for mass fluxes below 400 kg m −2 s −1 under near atmospheric pressure. It is found that flow oscillations can drastically reduce the CHF, in particular for natural-circulation conditions. In addition to the experiments, CHF correction factors for flow oscillation effects are developed for forced and natural circulations, respectively, based on the experimental data of the present work and others.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.