Abstract

In this study a method to predict CHF (Critical Heat Flux) in vertical round tubes with cosine heat flux distribution was examined. For this purpose a uniform correlation, based on local condition hypothesis, was developed from 9,366 CHF data points of uniform heat flux heaters. The CHF data points used were collected from 13 different sources had the following parameter ranges: 1.01 ≤ P (pressure) ≤ 206.79 bar, 9.92 ≤ G (mass flux) ≤ 18,619.39 kg/m2s, 0.00102 ≤ D (diameter) ≤ 0.04468 m, 0.0254 ≤ L (length) ≤ 4.966 m, 0.11 ≤ qc (CHF) ≤ 21.42 MW/m2, and −0.87 ≤ X (exit qualities) ≤ 1.58. The result of this work showed that the uniform CHF correlation could be used to predict CHF accurately in a non-uniform heat flux heater for wide flow conditions. Furthermore, the location, where CHF occurs in non-uniform heat flux distribution, can also be determined accurately with the local variables: the system pressure (P), tube diameter (D), mass flux of water (G), and true mass flux of vapor (GXt). The new correlation predicted CHF with cosine heat flux, 297 data points from 5 different published sources, within the root mean square error of 12.42% and average error of 1.06% using the heat balance method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.