Abstract
This paper presents experimental CHF data obtained for vertical up flow in an 8 mm I.D. test section, for a wide range of exit qualities (5–75%) and exit pressures ranging from 5 to 40 bar. The experiments were carried out for heated lengths of 0.75, 1, 1.4, 1.8, 2.5 and 3.5 m. A number of different coordinate systems are used to present the experimental results, these include CHF as a function of the inlet subcooling, as a function of the outlet thermodynamic quality, and as a function of the boiling length. An analysis of these commonly used representations of the CHF, has shown, that for all of the cases studied, the critical heat flux is dependent in some manner on the heated length. This dependence greatly complicates the possibility of obtaining a universal correlation for the critical heat flux at low and medium pressures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.